Solis WIFI Stick Troubleshooting TOP 5 Issues: 1. We and our partners use cookies to Store and/or access information on a device. Verify the address is set to "1". The setup process for the SolisWifiData Logger is fairly similar to the Cellular Data Logger's process. Shows the connection status between the datalogger and the inverter. logger's local network which allows you to link it to the home network. Press and hold power button to turn on your hotspot. Press the button for 5 seconds to reset, 2 red lights are on and off at the same time, https://www.youtube.com/watch?v=nUjcDcY8-Ws, Solis DLS-G GPRS Datalogger setup and troubleshooting, Solis RHI HMI Update German Documentation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. I will ask AGL for a replacement. If the WIFI stick shows the inverter but you don't have data on the monitoring portal follow these steps: If it is not pingable verify the router password again. No-Grid - El inversor no reconoce la red. The [RESET] button on the back is used for the connection. Users can easily check device lnformatlon by logging In the monitoring center. Enter the password for the network and then tap "Next". Help us improve this article with your feedback. You will need to have the, Unscrew the protective cap over the green COM port on the bottom of the inverter's wire box. Every solar system, regardless of size and complexity benefits from monitoring and this datalogger is the gateway to the informative online platform, SolisCloud. Log in to the page , the username is "admin" and the password is also "admin" 5. It's probably just the datalogger that's lost connection. Simple connectivity has your Solis solar system online in just a few steps delivering ongoing comprehensive data analysis and fault finding anytime, anywhere. Select Network, fill in the IP address assigned by the router/network administrator, 1: Connect LAN stick to operational inverter to provide power to LAN stick. I've recently installed a 6.6kW system for my home with a Solis Inverter. Solis Data Logging Stick GPRS/WiFi Installation Video Solis 46.7K subscribers 15K views 9 months ago Solis monitoring system is centred around the photovoltaic power station, focusing on. View the total data of your PV plant. A Wifi-enabled mobile phone is connected to this device parameter setting. Any changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. network that uses symbols in the password. Solis monitoring system is centered around photovoltaic power station, focusing on service operation and maintenance, Remotely controlled,adopting plug and play connection. Connect to WIFI stick and verify firmware. Solis Monitoring. Continue with Recommended Cookies, Home solis solis S3-WIFI WiFi Stick Datalogger Installation Guide, WiFi Stick Datalogger QuickInstallation ManualVersion: 3.1. solis app gone off-line MATTYON Apr 14, 2022 hi all my Solis app has stopped giving info since about 1 am with message "Current plant offline, Please check network connection of plant device" i wont get to it until tonight has anyone seen this before is it just the wifi (or has the whole system gone down) and will re-booting the system put it right Then click Done. Well also assume you agree to the way we use cookies and are ok with it as described in our Privacy policy, unless you choose to disable them altogether through your browser. Let us know how can we improve this article! This process can also be used to move a Solis Data Logger from one site to another. You should see a message that says "Bound Successfully" and now you will need to set up the logger on the localWiFinetwork. Wi-Fi trensmitting power: 802.11b/g/n: +20dBm/+18dBm/15dBm (Max) Data collection intervals: 5 minutes (adjustable:1-20 minutes) Preferences setting: Web server/Serial AT instruction. Open theSolisCloudapp on your phone. Solis is one of the oldest and largest global string inverter specialists that manufactures single-phase inverters, three phase inverters and energy stroage inverters for residential, commercial and utility scale PV systerms . If you have aSolisCloudaccount already, then please follow the steps below to create a plant and commission a SolisWiFidata logger to the system. Note: the logger is unable to connect to any. Plug the provided charging cable into Skyroam Solis and connect to a power source. 2. Unscrew the protective cap over the green COM port on the bottom of the inverter's wire box. Almost all of their products have an Modbus RS-485 interface for reading live status and statistics.. ESP8266 Solis to InfluxDB logger. Gua rpida de instalacin del sistema de monitoreo para Mxico y Centro Amrica. Once the logger is scanned it will be added to the system. Open the SolisCloud app on your phone. You can rerun the wizard and see if that works. SolisCloud intelligent software enables systems to be commissioned, monitored and maintained remotely saving time and money for installers and empowering . *, We appreciate your effort and will try to fix the article. Monitoring Accessory Configured But Still Won't Link? Victor is the author of this solution article. Data Logger into the port and be sure to secure it by tightening the black connector. Hi Everyone, I got some help with the Ginlong Wifi and I have been able to set the system up and log onto the Ginlong monitoring websitebut the system says it is 'loading' but no data is shown on the site. Select Network, fill in the IP address assigned by the router/network administrator LAN Stick - DLS-L 1: Connect LAN stick to operational inverter to provide power to LAN stick. 125K Multi-Input Inverter: No Paralleled DC Strings Allowed! If you have not already been registered on, It is highly recommended to first connect your phone to the home network that you wish to connect the, logger to. signal at the inverter for there to be a stable connection. If its not either move the inverter closer to the router, the router closer to the inverter or use a repeater to boost the strength. Plug the logger into the inverter - be sure the inverter is on with at least DC power, Open the Wi-Fi settings on your phone and then search for new networks, Look for a network called "Solis_XXXXXXXXXX" the "XXXXXXXX" should be the serial number of the logger, Open a browser on your phone and enter 10.10.100.254 into the address bar, Enter "admin" for the password and "123456789" for the password then hit Log In, Go to Quick Set and then tap Search in the top left corner, Select the local Wi-Fi network that you wish to use, Enter the Wi-Fi network password (be sure that it is correct) and then tap Save, If everything was done correctly, the "Solis_XXXXX" network should disappear and the NET/COM lights on the logger should begin flashing, At this point you can go to SolisCloud and add the data logger to your plant, Use the scanner to scan the QR code sticker on the logger, Place your hand behind the logger if the scanner is not working (this helps it to focus), If you are still not having luck scanning the logger you can enter the serial number manually, Go to the Device tab on your plant and then to the Data Logger tab, The data logger should now be displayed here with note about when it last reported. I too have recently tried to connect to the Ginlong data logger without success. Ginlong Solis is one of the world's recognised manufacturers of string solar inverters. Can AGL please provide some support (a guide that is user friendly in english rather than fractured english) to help me connect and gain access to my PV data. Otherwise, the communication quality may be affected. How do you connect Solis? This article is a guide for how to replace a Solis Data Logger on an existing system: one that has already been created in SolisCloud. 2. You will benefit from upgraded accurate fault alarm messaging that is adjustable to notify you within hours that fit meet your needs. Copyright@2019 Ginlong Technologies All rights reserved, Dec-17-2019, Go Solis Webinar: 2020 CA Solar Mandate Compliance with Solis Inverters, Feb-11-2020, Go Solis Webinar: New Solis 125K 1500V Inverters plus AlsoEnergy: Better ROI for 2-40 MW Systems, Mounting, Wiring, and Commissioning 4G Single Phase Inverter - Video, Solis and the Tigo TS4 Platform; Tested and Harmonized Commercial Inverter 690.12 Rapid Shutdown Solutions, Contacting Technical Support for Solis Partners, Contacting Technical Support for Your Region, Go Solis 2020 Webinar #7: Testing Solis Inverters Beyond Certifications with PV Evolution Labs, Go Solis Mini Exchange#1: An Introduction to Energy Storage System, Go Solis Webinar #1: 2020 California Solar Mandate with Solis Inverters (12/17/2019, U.S.), Go Solis Webinar #2: The New Solis 125K 1500V Inverters plus Also Energy (2/11/2020, U.S.), Go Solis Webinar #3: Solis Hybrid Energy Storage Inverter with LG Chem (2/11/2020, U.S.), Go Solis Webinar #4: Solis Commercial Inverters (4/21/2020, U.S.), Go Solis Webinar #5: Solis inverters and SunSpec Alliance (5/5/2020, U.S.), Go Solis Webinar #6: Solis and Tigo TS4 Platform - Tested and Harmonized Commercial Inverter 690.12 Rapid Shutdown Solutions, Go Solis Webinar #8 Solis Inverters and SunSpec Alliance: The Importance of SunSpec CSIP 2030.5, Ginlong Solis: Standard Lead Time from Ningbo to USA/Canada, How to Determine the Firmware Version of your Solis Inverter, Lowering Output Power of Single Phase Solis Inverter, MA Compatibility Between Single Phase 4G and 2G inverters, Solis 3PH and CSI GS Product Number and Description 20180331, Starting Serial Numbers and HMI VER- ISO-NE / Rule 21 P1 and P3, String Sizing for 1P and 3P Inverters. Unscrew the protective cap over the green COM port on the bottom of the inverter's wire box. Please follow the instructions below: Step3: Use your mobile phone to send a text message to the SIM card in the stick. Go to your web browser - Input 10.10.100.254 4. Thanks for your help, my data logger looks like it is faulty. Administrators, Computer Games Moderators, Sports Moderators, https://www.boards.ie/discussion/comment/118925467#Comment_118925467, https://www.boards.ie/discussion/comment/118925665#Comment_118925665, https://www.boards.ie/discussion/2058241657/solis-app-gone-off-line, https://www.boards.ie/discussion/comment/118926624#Comment_118926624, Music Production Commercial Victor is the author of this solution article. Solis DLS-G GPRS Datalogger setup and troubleshooting, Solis Data Logger Server Information - wyjtki w firewall'u, Pylon US2000C/US3000C Battery - CAN Failure - No Battery - Deutsch, Solis Data Logger Server Information - firewall exceptions. If you are scanning the loggers then be sure to scan the bar code on the logger itself and not the one on the inverter's spec label, see examples of the logger bar codes below: Establecer el estndar de red personalizado Definido por usuario, Valores de la configuracin USER DEF para red 240v y 480v, Procedimiento de actualizacin remota de firmware, Reduccin de la potencia de salida del inversor Solis monofsico, Instalacin de cable RS-485 con conector circular, Configuracin de la direccin en inversor trifsico, Restablecer WiFi-Stick a la configuracin de fbrica, Registro de usuario final al sistema de monitoreo. Firmware Version: 3.16.9. i have recently installed a solar inverter which has a data logger > having an issue connecting it to my wifi network but it works fine with . If it does not reconnect than with your laptop/phone search for new open access point and try to connect to wifi stick, maybe it has lost settings. Solis WiFi Loggers Network Strength Requirements, Solis Home Professional - Generation 2 Monitoring Platform, Account Transfer to New Monitoring Platform, Adding End-User (Customer) to Plant for Monitoring Access, Selecting Inverter Drivers on AlsoEnergy PowerTrack Monitoring, Inaccurate Production Data on Monitoring Portal, Registering Installer Account on G2 Portal, Setting Up Agency Access to Plant Monitoring, Enabling SMS Notifications on SolisCloud App, How to Create an Installer Account on SolisCloud, Create Sub-Organizations, & Manage Sub-Accounts, Deteccin falla de arco y solucin de problemas, Pantalla en blanco / LCD en blanco / Sin luces. I had to go up to the attic and actually point the antenna towards my router. Please provide the following information as well: Ginlong Technologies Co., Ltd.No. With permission, you can test the firewall by removing the firewall for 5 minutes to see if the communication with the remote server changes to pingable. SolisCloud intelligent software enables systems to be commissioned, monitored and maintained remotely saving time and money for installers and empowering system owners with all the data they need. No-Grid - El inversor no reconoce la red. Once you've connected to the "AP" network, return toSolisCloudand then look for the home network that you wish to connect the logger to. Communication quality may be affected in lightning storms. Well also assume you agree to the way we use cookies and are ok with it as described in our Privacy policy, unless you choose to disable them altogether through your browser. 4: Once the computer IP is set with the above details open a web browser and navigate to 10.10.100.254 to login to LAN stickadmin page. Solis is one of the oldest and largest global string inverter specialists that manufactures single-phase inverters, three phase inverters and energy stroage inverters for residential, commercial and utility scale PV systerms . With solis2influx.ino one can read out all inverter data (status and statistics) via Modbus and push it to InfluxDB. A Solis 5K inverter is used here as an example. Solis Data Logger Server Information - firewall exceptions Modified on Fri, 09 Dec 2022 at 02:15 PM When the network environment of the plant has a firewall, you need to add the server information to the white list of the firewall. Open the Local Connection Status, clickon Properties, select internet protocol IPv4(TCP/IPv4). No-Grid - El inversor no reconoce la red. Start by opening yourWiFisettings and then connecting to the network that starts with "AP" - this is theWiFilogger's local network which allows you to link it to the home network. Copyright@2020 Ginlong Technologies All rights reserved, Data Logger is fairly similar to the Cellular Data Logger's process. RHI-1P(5-10)K-HVES-5G Operation & Troubleshooting, Arc-Fault Alarm Troubleshooting for RHI-1P(5-10)K-HVES-5G, Advanced Hybrid DSP Issues - Replacing the DSP Board, Export Power Set and FailSafe Configuration, MET_Comm-FAIL and RS485 Fail Troubleshooting, Modbus Communications for RHI-1P(5-10)K-HVES-5G-US, Solis String-Level RSD Troubleshooting Procedures, Solis-(75-100)K-5G Tigo MLRSD Transmitter Disabling, Solis-1P(5-10)K-4G SunSpec MLRSD Transmitter Disabling, RHI-1P(5-10)K-5G SunSpec MLRSD Transmitter Disabling, RHI-1P(5-10)K-5G Tigo MLRSD Transmitter Disabling, Solis S1-W4G-ST WiFi & Cellular Data Logger Set Up Guide, Solis S3-WIFI-ST Wi-Fi Data Logger Setup Guide, Solis DLS-W WiFi Data Logger Installation Guide, Solis Cellular Data Logger Installation Guide, Solis DLS-C Cellular Data Logger - Carrier Compatibility, WiFi Stick Not Working With WiFi Extender Network. Connect the data logger to the corresponding 4-pin COM port of the inverter. Connect to the inverter (to get power), 3. Step 5: Scan the SN number of the datalogger or manually input it.Note: Scan the datalogger SN, NOT the inverter SN. solis S4-GPRS GPRS Stick Datalogger Installation Guide, solis SOL-DLS-W Data Logger Wifi Stick User Guide, DAIKIN BRP069B45 WiFi Adapter Installation Guide, ideal lux 306445 Clara PL Square 4000K Ceiling Light Owners Manual, Microderm GLO NVD-MGM-GR1802 Blackhead Remover Pore Vacuum User Guide, AVALON A3F Bottom Loading Water Cooler Water Dispenser User Manual, boAt Wave Lynk Voice Premium Smartwatch User Manual, motorline RAP50 Microwave Presence Sensor User Manual, kbice FDFM1JA01 Self Dispensing Nugget Ice Machine User Guide, LUMINAR EVERYDAY 59250 2ft LED Linkable Plant Grow Light Owners Manual, Viatom Blood Pressure Monitor BP2 & BP2A User Manual. Your email address will not be published. It may also be affected by lighting storms. If its not broadcasting conduct this procedure - https://www.youtube.com/watch?v=nUjcDcY8-Ws - If that doesn't fix the issue of it broadcasting please contact your local Solis Service Center and RMA the WIFI Stick. S-Energy 320W modules, Terminal Torque Specs by Inverter Model Series, Advisory Bulletin July 2019 - New DC Switch Color of Red on Single Phase, Application Notes: Rapid Shutdown AC Wiring with Multiple Inverters, Rule 21 Phase 1 July 26th Changes 1P and 3P, Solis RSD Letter For Jurisdiction Acceptance, Spring Terminals Installation and Removal, RHI-1P(5-10)K-5G with BYD HV Commissioning Guide, Solis RHI-1P(5-10)K-HVES-5G Installation Guide, 5 of 20 - Installing the External Meter and CTs, 7 of 20 - Inverter Menu Overview and Selecting the Grid Standard, 8 of 20 - Installing & Commissioning the BYD B-Box HV Battery, 9 of 20 - Installing LG Chem RESU10H Battery (Mounting), 10 of 20 - Installing LG Chem - Wiring and Commissioning, 11 of 20 - Energy Storage Operating Modes - Self Use, 12 of 20 - Energy Storage Operating Modes - Feed-In-Priority, 13 of 20 - Installing the Solis Autotransformer, 14 of 20 - Installing the Backup Loads Subpanel and Selecting Critical BreakersLoad, 15 of 20 - Energy Storage Operating Modes - Backup and Off-Grid Modes, 17 of 20 - Module-Level Rapid Shutdown (MLRSD), 18 of 20 - SolisCloud Monitoring Platform, Installation Overview & Single-Line Diagrams, Solis Inverter Alarm Codes (Complete List), NO-Grid Fault - The inverter does not recognize the AC grid, Firmware Updating Guides & Firmware Files, Solis Inverter Current Firmware Versions [Master List], RHI-1P(5-10)K-HVES-5G inverters DSP firmware updating process, RHI-1P(5-10)K-HVES-5G inverters HMI firmware updating procedure, Solis-1P(3.6-10)K-4G inverters DSP firmware updating process, Solis-1P(3.6-10)K-4G inverters HMI firmware updating process, Solis-(25-40)K-4G inverter DSP firmware updating procedure, Solis-(25-40)K-4G inverter HMI firmware updating procedure, Solis-(50-66)K-4G inverters DSP firmware updating procedure, Solis-(50-66)K-4G inverters HMI firmware updating procedure, Solis-(75-100)K-5G-US inverter DSP Firmware Updating Procedure, Solis-(75-100)K-5G inverter HMI Firmware Updating Procedure, Solis-125K-EHV-5G inverter DSP firmware updating procedure, Solis-125K-EHV-5G inverter HMI firmware updating procedure, Solis-(185-255)K-EHV-5G inverter DSP firmware updating procedure, Solis-(185-255)K-EHV-5G inverter HMI firmware updating procedure, Setting a custom (user-defined) grid standard, US Grid Standards (values) // confidential //. Solis S1-W4G-ST WiFi & Cellular Data Logger Set Up Guide; Solis S3-WIFI-ST Wi-Fi Data Logger Setup Guide; Solis DLS-W WiFi Data Logger Installation Guide; Solis Cellular Data Logger Installation Guide; Solis DLS-C Cellular Data Logger - Carrier Compatibility; Replacing a Solis Data Logger; WiFi password changed; Reset WiFi Stick to Factory Settings The consent submitted will only be used for data processing originating from this website. This should serve as a reminder to manually save your drafts if you wish to keep them. Solis inverter - Ginlong data logger Solar, Batteries & Technology Questions and discussion about solar, batteries, and other renewable energy technology Solis inverter - Ginlong data logger Comet 08-05-2018 09:43 PM 6 Replies 1 Like 45040 Views Hi We have just had a solar system installed. A Solis 5K inverter is used here as an example.Please follow the instructions below:Install the datalogger: NOTEOnly rotate the black circle, not the sliver cover. Have contacted the company who sold me it. 2.4 GHz. Solis WiFi Loggers Network Strength Requirements, Solis Home Professional - Generation 2 Monitoring Platform, Account Transfer to New Monitoring Platform, Adding End-User (Customer) to Plant for Monitoring Access, Selecting Inverter Drivers on AlsoEnergy PowerTrack Monitoring, Inaccurate Production Data on Monitoring Portal, Registering Installer Account on G2 Portal, Setting Up Agency Access to Plant Monitoring, Enabling SMS Notifications on SolisCloud App, How to Create an Installer Account on SolisCloud, Create Sub-Organizations, & Manage Sub-Accounts, Deteccin falla de arco y solucin de problemas, Pantalla en blanco / LCD en blanco / Sin luces. Yes logger can only connect to 2.4 GHz networks and is unable to connect to 5 GHz networks. Tap the Plant icon in the bottom left corner of the screen, Tap the plus sign in the top right corner and then tap "Add Plant", Fill in all of the required fields on the "Create Plant" page and then tap "Done" in the top right corner, Tap "Create Plant" to finish making a system inSolisCloud- tap "View Plant" once it gives you a big check mark, When the plant page opens, you will receive a message saying "No datalogger was added, please add a datalogger" tap "Add" if theWiFidata logger is plugged into the bottom of the inverter, A scanner will automatically come up. Intro Inverter Logger Device Connect Summary Device Make Sure Phone Connected to WiFi Network Please Make Sure Phone Connected to WiFi then Click Next 15:38 Back Connect WiFi SN: 4005854756 Enter Netwo. Press the button for 5 seconds to reset2 red lights are on and off at the same time. it tries to reconnect itself vut you can just unplug it and plug it back. 1. 4G Next COnfigurate Connection 15:30 Back Enter the plant name Done Plant Name Connect to the datalogger - AP_XXXXXXXXXX 3. Solis S1-W4G-ST WiFi & Cellular Data Logger Set Up Guide; Solis S3-WIFI-ST Wi-Fi Data Logger Setup Guide; Solis DLS-W WiFi Data Logger Installation Guide; Solis Cellular Data Logger Installation Guide; Solis DLS-C Cellular Data Logger - Carrier Compatibility; Replacing a Solis Data Logger; WiFi password changed If it is not pingable and the password is good, then verify the signal strength of the WIFI Router, 3. Model: AP300 Hardware Version: V11. Category: Monitoring and Communication If you would like to change your settings or withdraw consent at any time, the link to do so is in our privacy policy accessible from our home page.. Solis Inverter Data Logger Issue. This video will. I have done a bit of Googling and the only negative thing I have read about the data logger is that it can lose it's wifi connection easily. If there are symbols in the password, it must be changed or the logger will not connect to it. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. Please follow the process for installing a new data logger. 3: Set a manual IP for the computer using the following information -, (The IP of the computer must be with 10.10.100.XXX range to configure the LAN stick). If it is set to one verify the WIFI stick has a good connection to the inverter. 2023 AGL recognises the Aboriginal and Torres Strait Islander peoples as the Traditional Owners of the lands on which we work, and we acknowledge those communities' continuing connections to their lands, waters and No, Modified on: Fri, Jun 10, 2022 at 11:55 AM. 5. Select Network, fill in the IP address assigned by the router/network administrator, Let us know how can we improve this article! AC Voltage Offset Procedure and Firmware Requirements, Service - Modbus Issues - Troubleshooting, LCD Protective Sticker Replacement Procedure. cultures. If you are verifying the connection on m.ginlong.com or pv.ginlong.com please allow 5-10 minutes for the updates to appear. Connect one end of an ethernet cable to LAN stick, 2: On the computer, click on the Network Connections and select the Local Connection. 125K Multi-Input Inverter: No Paralleled DC Strings Allowed! Screenshot of the Status page in the configuration interface. Monitoring Accessory Configured But Still Won't Link? No, Modified on: Tue, Oct 4, 2022 at 2:54 PM. Yes my data logger also glows red as well, does appear to be a LED keepalive in the unit to show its still transmitting data to the mothership. The replacement is working brilliantly. Thanks Peter. 2. Solis monitoring system can be monitored remotely by WIFI and GPRS to provide users accurate and comprehensive data analysis and fault alarm at any time and place, this makes product operation more stable and reliable, and realize stable and intelligent operation and maintenance management services. Connect to the inverter (to get power) 3. Internal DC Short: In the inverter head, or the wirebox? Yes Shows the connection status between the datalogger and the server. Solis Data Loggers. If you hate cookies, or are just on a diet, you can disable them altogether too. The warranty shall be executed by the terms included here but not limited to PO/Pl/Cl of goods. RHI-1P(5-10)K-HVES-5G Operation & Troubleshooting, Arc-Fault Alarm Troubleshooting for RHI-1P(5-10)K-HVES-5G, Advanced Hybrid DSP Issues - Replacing the DSP Board, Export Power Set and FailSafe Configuration, MET_Comm-FAIL and RS485 Fail Troubleshooting, Modbus Communications for RHI-1P(5-10)K-HVES-5G-US, Solis String-Level RSD Troubleshooting Procedures, Solis-(75-100)K-5G Tigo MLRSD Transmitter Disabling, Solis-1P(5-10)K-4G SunSpec MLRSD Transmitter Disabling, RHI-1P(5-10)K-5G SunSpec MLRSD Transmitter Disabling, RHI-1P(5-10)K-5G Tigo MLRSD Transmitter Disabling, Solis S1-W4G-ST WiFi & Cellular Data Logger Set Up Guide, Solis S3-WIFI-ST Wi-Fi Data Logger Setup Guide, Solis DLS-W WiFi Data Logger Installation Guide, Solis Cellular Data Logger Installation Guide, Solis DLS-C Cellular Data Logger - Carrier Compatibility, WiFi Stick Not Working With WiFi Extender Network. The