HOTFire is a free online site that helps users quickly plan and model notification appliance circuits (NACs) using the entire line of SpectrAlert Advance and L-Series. A INSTALLATION AND MAINTENANCE INSTRUCTIONS. System Sensors intelligent and conventional modules are designed to help you meet a wide range of application requirements. Notify the proper authorities that the system is in operation. C. Direct Heat Method (models 2WT-B and 4WT-B only) The Companys obligation visual status indication at each detector. Near fresh air inlets or returns or excessively drafty areas. It can connect with a Honeywell VISTA System at Zone 1. Product specifications subject to change without notice. POWER . Two LEDs on the detector provide a local visual indication of the detectors status: IMPORTANT: This detector must be tested and maintained regularly following Twisted pair may be used to provide additional protection Two-Wire Compatibility Dust covers are an effective way to limit the entry of dust into the smoke detector sensing chamber. performed and the system will be temporarily out of service. 5. $5899 $69.99. List Price $134.00 Our Price $88.99 You Save $45.01 (34%) Unlike traditional detection systems, Reflected Beam Smoke Detectors were designed for spacious rooms, open areas, and high ceilings; their innovative features make them popular choices for spaces like warehouses, atriums, arenas, and churches. 15 sec I have an old System Sensor 2 wire photoelectric smoke alarm (hardwired) that is about 17 years old and has finally gone out - trying to figure out if this particular unit will work seamlessly as a replacement for my existing alarm - there is a connection to the back of the alarm and wonder if I can just hook up the new alarm the same away the old alarm is connected and have it work? VIEW MODELS Beam Smoke Detection Fill out our feedback form! Freeze Trouble (Model 2WT-B and 4WT-B): Buy the System Sensor 2WTA-B Smoke and Heat Sensor from Alarm Grid. Vacuum the cover or use canned air to remove any dust or debris. Are a Smoke Alarm and a Smoke Detector The Same Thing? 2WT-B and 4WT-B: Light settings: The brightness sensor is activated, it automatically switches between daytime Operating Temperature Range: Please send an email to support@alarmgrid.com referring to this inquiry to better assist you with your 20P. CAUTION be used in lieu of the tests specified under Testing. 6.3 oz. Near fresh air inlets or returns or excessively drafty areas. Explore System Sensor products including: AV Notification, Beam Smoke detection, CO detection, HVAC Smoke detection, spot smoke detection, relays, & modules. The LED indication must not, be used in lieu of the tests specified under Testing. NOTE: T This Warranty gives you specific legal rights, and you I have since replaced the battery, which has resolved the smoke error. The microprocessor allows the detector to automatically adjust its of smoke detectors. Travis, with 4-wire smokes, you usually don't have to verify compatibility. *Refer to Electrical Specifications for start-up time in conjunction with panel Initial LED Status Indication. Brightness sensor Mode The sensor is activated. In a freeze trouble condition, the red LED will blink once every 10 seconds (refer to Table 1). switch opening; push and hold. Do NOT Install Detectors in the Following Areas: detector which is found to be defective in materials or workmanship under normal use Holes. Users of this calculator are solely responsible for their own selection and use of products based upon information contained in this calculator and any calculations from this calculator. Before Installing 130 Air conditioners, heaters, fans, and fresh air intakes and returns can drive smoke After power up, allow 80 seconds (See the Testing section.) 4.Direct mount or to ceiling using drywall fasteners (Figure 2). list is available from System Sensor upon request. Please read thoroughly System Sensor manual A05-1003, Applications Guide DSC NEO: System Sensor 2-wire smoke wiring and programming This video showcases the wiring and programming for 2-wire smokes on a DSC NEO security system. J#_l Uf! z8wE]Kz[]~F$e.7 0hHJUm0C TXopU* 8CC]s9AdZJ:>iSiO8hwRYlY goih5KN&XIJe\[% I have a Vista 6150 15P Control Panel and an old System Sensor 2312/24TB 4 wire Smoke/heat detector. against extraneous electrical interference. 6. The 2W-B is a 2-wire, photoelectric i3 smoke detector. alarm verification. If the detector is within the listed sensitivity limits, the detectors red any latin characters (a-z, A-Z) any numbers (0-9) special characters ("-", "_" and ". condition if the temperature is below 41F. Max. 4-Wire Smoke Detector with 135F Fixed Heat Sensor, 2-Wire Smoke Detector with Fixed Heat Sensor, System Sensor 2W-B, 2WT-B, 4W-B & 4WT-B - Installation Guide. 3. Series 2W-MOD module (refer to installation manual D500-46-00), the 2W-B and 2WT-B are capable of generating a "maintenance. detectors to the alarm control panel and accessory devices should be colorcoded to reduce the likelihood of wiring errors. endstream endobj 473 0 obj <> endobj 474 0 obj <> endobj 475 0 obj <> endobj 476 0 obj <> endobj 477 0 obj <> endobj 478 0 obj <>stream 2W-B Datasheet (HTML) - Systemsensor advanced ideas. The screw terminals in the mounting base will accept 1422 gauge wire. system or the conduit, both LEDs will blink for up to 4 minutes before displaying detector status (see Table 2). Figure 1: Mounting of Detector. Have feedback about a particular System Sensor product? Height (including base): 2W-B Datasheet (PDF) - Systemsensor advanced ideas. Hold the heat source about 12 inches from the detector to avoid damage Fire Alarm Systems | System Sensor L-series indoor horn/strobes System Sensor L-series indoor horn/ strobes www.boschsecurity.com u u Plug-in design with minimal intrusion into the back box u Field-selectable candela settings of 15 or 30 cd at 12 V or 15, 30, 75, 95, 110, 135, and 185 cd at 24 V u Horn rated at 88+ dBA at 16 V Rotary switch for horn tone and two volume settings A, System Sensor i3 series 2w-b, 2wt-b, 4w-b, 4wt-b Data Sheet. further simplified by the incorporation of features compatible with drywall Smoke Entry Test In no case shall the Company be liable for any consequential or incidental damages for needed" signal. It sounds like a short problem somewhere in the smoke lines to me, but I am not sure. 30 OVAL AREA OR AT THE IMPORTANT: This detector must be tested and maintained regularly following NFPA 72 requirements. And today we're going to be adding two-wire smokes to our DSC Neo system. System Sensor two-wire smoke detectors are marked with a compatibility identifier located on the label on the back of the product. With less intelligent smoke detectors, a dirty photoelectric chamber will results in false alarms. Also, is your system currently monitored we do offer no contract low cost monitoring plans as low as $10/mth. It sounds like you may be experiencing a low battery issue possibly. Installation of the 2W-B, 2WT-B, 4W-B, and 4WT-B detectors is simplified by It should connect the same exact way. If the detector is in need of maintenance because its sensitivity has shifted outside the listed limits, the red LED blinks once every five seconds. System Sensor webinars provide relevant and timely information on products, market trends, and legislation. detector to finish the power-up cycle (see Table 2). Our understanding is that EASE Evac voice evacuation design software from AFMG Technologies is intended to help designers and installers save time and money on voice evacuation systems by enabling them to preplan the system to meet new intelligibility code requirements, reduce costly post-installation changes, and limit over-design. Figure 3a: Wiring Diagram, 2W-B and 2WT-B. 2. Ensure proper wiring and power is applied. The 2W-MOD2 installation manual may be downloaded from the The i3 Series heads and bases are keyed so that a 2-wire head will only mount to a 2-wire base, and a 4-wire head will only mount to a 4-wire base. System Sensor warrants its enclosed smoke detector to be free from defects in materials This item: System Sensor 2W-B i3 Series 2-wire, Photoelectric i3 Smoke Detector $52.42 UHPPOTE Wired Sound and Light Fire Alarm Warning Strobe Siren Horn Sound Alert Safety System $18.40 Fire Lite Alarms Dual Action Pull Station w Key Lock $57.06 Honeywell VISTA-20P Ademco Control Panel, PCB in Aluminum Enclosure 399 12 offers from $73.62 endstream endobj 1001 0 obj <>>>/EncryptMetadata false/Filter/Standard/Length 128/O(19[nMM\\.9rvXbp)/P -1036/R 4/StmF/StdCF/StrF/StdCF/U(bH;^Soe9ACM )/V 4>> endobj 1002 0 obj <> endobj 1003 0 obj <>/ExtGState<>/Font<>/ProcSet[/PDF/Text/ImageB]/XObject<>>>/Rotate 0/Type/Page>> endobj 1004 0 obj <>stream 7.7K views 1 year ago DSC Power Series Neo Installation Series Two wire type smoke detectors are arguably the simplest smokes to use with an alarm system, yet we still get installation questions. Visit systemsensor.com for current product information, including the latest version of this data sheet. testing. Consult the list to locate a control module for your specific fire alarm system. At a minimum, cleaning should be performed annually. System Sensor two-wire smoke detectors are marked with a compatibility identifier located on the label on the back of the product. 2-Wire i3 Detector Wired in Style D Configuration: B. We're here to help with any issues or questions. We're here to provide technical support for System Sensor products and service. the incorporation of features compatible with drywall fasteners. 8. 3825 Ohio Avenue, St. Charles, Illinois 60174 The System Sensor 2W-B smoke detector has a sensing chamber that that will become dirty with dust over time. System Sensor 2WTA-B specifications Below you will find the product specifications and the manual specifications of the System Sensor 2WTA-B. 2.0 inches System Sensor - Technical Field Bulletin Life Expectancy of System Smoke Detectors - Dated 05/2012, Limitations of Fire Alarm Systems - Dated 5/13 Rev. 2W-B and 2WT-B, connect detectors only to compatible alarm control panels System Sensor BK-2WB Photoelectric i3 Series Smoke Detector, 2-Wire, White Brand: System Sensor ADI #:BK-2WB Model #: 2W-B Name: System Sensor BK-2WB Photoelectric i3 Series Smoke Detector, 2-Wire, White Plug-in detector line, mounting base included Large wire entry port In-line terminals with SEMS screws Product Overview Installation ease. Electrical Specifications 2-wire 4-wire Min. Thank you for the response @disqus_YuNiL6S1Rn:disqus. 12/24 Volts Non-polarized When mounting the i3 Series, ensure that the head is mounted to the correct base. The Explore System Sensor like white papers, announcements, technical bulletins, case studies, and more. The device uses photoelectric technology to detect smoke, while the fixed heat sensor activates at temperatures of 135F and higher. To test this please remove AC power and set the panel into alarm mode to see if the battery will support the system and report back. ANSI/UL 1971 does not provide ratings for each angle based on actual test results.". The LED indication must not System Sensor makes no representations whatsoever with regard to the quality or function of AFMGs EASE Evac software. Insert a small screwdriver or allen wrench (0.18 max.) DETECTOR Test Switch A05-0395-007 4/09 #2132 SpectrAlert Advance Dimensions Model Description Wall Horn Strobes P2R* 2-Wire Horn Strobe, Standard cd, Red InnovairFlex duct smoke detectors combine an impressive collection of innovations to greatly simplify HVAC system monitoring. For two-wire models 2W-B and 2WT-B, connect detectors only to compatible alarm control panels as identified by System Sensors compatibility chart. 1. NOTE: To install units so that corresponding LEDs are lined up, refer to the Add the hardwired 2W-B smoke detector to most existing alarm system control panels. Therefore, System Sensor recommends Peak Standby Current: Deciding Whether to Use 2-Wire or 4-Wire Smoke Detectors. prevent a system from responding properly in the event of a fire. You'll never be more than a mouse click away from the information you need to make informed decisions about our products and their capabilities. Please read thoroughly System Sensor manual A05-1003. breach of this or any other Warranty, expressed or implied whatsoever, even if the loss Buy the System Sensor 2WT-B here. for the detector to stabilize before testing. This includes cleaning, maintenance or screen replacement. Z@~P]%*?p S_iVN$rtE;[\SmgisL^aOTYVE \xOQc_m1eN"hB~n5#{f-!tEn -:)D#bBc7yo0x&i9Su%t wa+"i Increase the separation between the equipment and receiver. The 2W-B should work zones 1 and 2 since they are designed for system sensor 2-wire devices. The 2W-B smoke detector works with most Honeywell alarm control panels including the VISTA-20P and VISTA-21iP as System Sensor is a subsidiary of Honeywell. This chart contains the To stay in the know on upcoming news and announcements, subscribe. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. For two-wire models 2W-B and 2WT-B, connect detectors only to compatible alarm control panels as identified by System Sensor's compatibility chart. 6. optional Model RA400Z Remote Annunciator to be connected. 2W-B and 4W-B: Should it become necessary, the screen/sensing chamber is field replaceable. 2. A. Any advice/help would be greatly appreciated. PipeIQ guides users through the initial pipe layout and system configuration for a FAAST aspiration system. After power-up has completed and the detector is functioning normally within models must be used with compatible UL Listed panels only. RA400Z Remote Annunciator to be connected. Some parts of this page is temporarily unavailable. Enter your email address and check your inbox. These limits are designed to provide 23 mA 24 Volt Systems To engage the tamper-resistant feature, cut the small plastic tab located on the mounting base (Figure Make sure to observe polarity when wiring up your smoke detectors and you should connect an end-of-line resistor across the loop wires at the last 2W-B on your loop. If the detector is in need of maintenance, because its sensitivity has shifted outside the listed limits, the red, LED blinks once every five seconds. 4.8 out of 5 stars based on 20 product ratings, 4.8 out of 5 stars based on 166 product ratings, 4.9 out of 5 stars based on 174 product ratings, 4.8 out of 5 stars based on 175 product ratings, 4.8 out of 5 stars based on 190 product ratings, 5.0 out of 5 stars based on 1 product rating. If they are not just take a photo of the connections and land what is connected to the positive connection the new plates positive and same with the negative. We are notifying you about EASE Evac as a service to our customers as it may simplify voice evacuation design. Testing Weight: particles from entering the detector. Two-wire The 2W-B smoke detector works with most Honeywell alarm control panels including the VISTA-20P and VISTA-21iP as System Sensor is a subsidiary of Honeywell. or system undergoing maintenance to prevent any unwanted alarms. NOTE: Before testing, notify the proper authorities that maintenance is being Compatible with SENS-RDR sensitivity tester; Full agency compliance with UL 268 and UL 2075; Technical Specifications: System Voltage: 12/24 VDC; Heat Sensor (Model 2WT-B and 4WT-B): For the effect of polar distribution (rated candela at each angle), the ANSI/UL 1971 minimum percentages are used for the calculations. 100 I have a DSC alarm system that my current System Sensors are connected to and would I need to do anything special when I replace the old with the new other then reset the system? N/A N/A 120 System Sensor 2851B A Photo B101B / B107B A 120 System Sensor 2851BTH A Photo / Therm. KingOfTheP4s 3 yr. ago Best thing to do in this case would be to call the company of your choice, such as EST, and ask a sales representative to give you a list of MRI-safe devices. note describing the malfunction and suspected cause of failure. Features include a universal mounting plate with a preliminary snap-in feature to hold the product in place for the screw attachment, 7 field-selectable candela settings for wall and ceiling mount devices, and rotary switches to select horn tone and volume settings. However, there is no guarantee that interference will not occur in a particular installation. manual are available from System Sensor at no charge. endstream endobj startxref contaminants settling in its chamber. When used with an i3 Series compatible control panel or the i3 Series 2W-MOD module (refer to installation manual D500-46-00), the 2W-B and 2WT-B are capable of generating a maintenance needed signal. 4. This chart contains the current list of detectors and UL Listed compatible control units. indicate a need for cleaning, replacement, or a freeze condition (2WT-B only) 15 sec in the Style D initiating device circuit (IDC) configuration requires the use 1050 0 obj <>stream 135F (57.2C) 0.18 MAX. Max. Turn it on by pushing the button of the wired remote. A copy of this Blink 10 sec 2. item 2 System Sensor 2W-B I3 Series 2-Wire Photoelectric Smoke Detector, item 3 NEW System Sensor 2W-B 2WB i3 Series 2-Wire Photoelectric Smoke Detector Fire, item 4 System Sensor 2W-B i3 Series 2-wire, Photoelectric Smoke Detector, item 5 NEW System Sensor 2W-B 2WB i3 Series 2-Wire Photoelectric Smoke Detector Fire. Air conditioners, heaters, fans, and fresh air intakes and returns can drive smoke away from the detector. Just fill out the form and click your area of interest. Dimensions: 2.0" (51mm) H x 5.3" (127mm) Dia. 130 Connectivity. When I put the system in alarm mode and set it off, the panels still have the same behavior and the sirens (not the keypad alarm) do not sound. Models 2W-B and 2WT-B also include an output that allows an optional Model RA400Z Remote Annunciator to be connected. View a list of all System Sensor locations worldwide. Certain System Sensor SWIFT AV bases have the potential to generate a premature and erroneous low battery notification. Alarm, Red LED Remove power from alarm control unit or initiating device circuits before installing detectors. Some states do not allow the Follow the steps in the Tech Bulletin below to check your current firmware version and update your device firmware if needed.. The i3 Series heads and bases are keyed so that a 2-wire head will only mount Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must This calculator uses data provided by the user to perform the calculations described in NFPA 72, which permits the use of a performance-based alternative in lieu of tables for spacing ceiling mounted audible/visible devices. Copyright 2023 Honeywell International Inc. The CLSS Tool Suite allows you to perform battery, voltage drop, and Db line loss calculations in a single desktop application. All i3 Series detectors are designed to provide open area protection. After some recent electrical work (new AC unit in the attic) the vista 20p shows fire trouble, and occasionally sets off the alarm. Copies of this manual are available from System Sensor at no charge. System Sensor makes no other express warranty for this smoke detecbe obligated to repair or replace units which are found to be defective because of damage, System Sensor 2451 A Photo B401B / B406B / DH-400 / B110LP / B116LP A 120 System Sensor 2451TH A Photo / Therm. Replace the detector cover by placing it over the screen/sensing chamber 32 Degrees to 120 Degrees F. Battery Backup. Improper connections can prevent a system from responding properly in the event of a fire. fasteners. System Sensor products are designed and manufactured to meet or exceed various product safety and certification requirements. This includes cleaning. The panel has internal knowledge to reset the zone automatically when an alarm is cleared. To view our listings, please visit one of the following sites. Reorient or relocate the receiving antenna. for System Smoke Detectors, which provides detailed information on detector Power must be removed from the detector Heat Sensor (Model 2WT-B and 4WT-B): 135F (57.2C) Freeze Trouble (Model 2WT-B and 4WT-B): 41F (5C) Operating Temperature Range: 2W-B and 4W-B: 32 to 120F (0 to 49C) 2WT-B and 4WT-B: 32 to 100F (0 to 37.8C) Operating Humidity Range: 0 to 95% RH non-condensing Storage Temperature Range: -4 to 158F (-20 to 70C) Diameter (including base): Hello, I have a vista 20P (came with the house I bought) that has (4) 2 wire smokes wired in. It would be hard to rate this product at one star unless it was somehow responsible for an unreported house fire. The EZ Walk loop test verifies the initiating loop wiring and provides I still get the "shorted out keypad". There is a red and green LED on the head of the 2W-B smoke detector. This latest software also includes an enhanced interface for increased ease of use. Smoke Detectors with Sounder and Relay Option may also have other rights which vary from state to state. List Price. Wiring Installation Guidelines *Assumes the panels alarm verification reset time is 10 seconds or less. 0 to 95% RH non-condensing You can use up to sixteen 2W-B smoke detectors on the zone one fire loop. In a freeze, trouble condition, the red LED will blink once every 10 seconds, To measure the detector's sensitivity, the i, RDR Infrared Sensitivity Reader tool (see Figure 4) should be, Models 2W-B and 2WT-B also include an output that allows an. B101B / B107B A 120 Test i3 Series detectors as follows: An overview of latest updates, essential resources, and webinars. to 35 max. . : In a freeze trouble condition, the red LED will blink once every 10 seconds (refer to Table 1). 5. For two-wire models All wiring must be installed in compliance with the National Electrical Code, applicable state and local codes, and any special requirements of the local Authority Having Jurisdiction.